Title: Hand-Held Metal Detectors for Use in Concealed Weapon and Contraband Detection, NIJ Standard-0602.02 Series: Law Enforcement and Corrections Standards and Testing Program Author: Nicholas G. Paulter, Jr. Published: National Institute of Justice, November 2003 Subject: Technology in law enforcement and crime prevention 38 pages 67,000 bytes ---------------------------- Figures, charts, forms, and tables are not included in this ASCII plain-text file. To view this document in its entirety, download the Adobe Acrobat graphic file available from this Web site or order a print copy from NCJRS at 800-851- 3420 (877-712-9279 for TTY users). ---------------------------- U.S. Department of Justice Office of Justice Programs National Institute of Justice Law Enforcement and Corrections Standards and Testing Program Hand-Held Metal Detectors for Use in Concealed Weapon and Contraband Detection, NIJ Standard-0602-02 ---------------------------- U.S. Department of Justice Office of Justice Programs 810 Seventh Street, N.W. Washington, DC 20531 John Ashcroft Attorney General Deborah J. Daniels Assistant Attorney General Sarah V. Hart Director, National Institute of Justice This and other publications and products of the U.S. Department of Justice, Office of Justice Programs, National Institute of Justice can be found on the World Wide Web at the following site: Office of Justice Programs National Institute of Justice http://www.ojp.usdoj.gov/nij ---------------------------- U.S. Department of Justice Office of Justice Programs National Institute of Justice Hand-Held Metal Detectors for Use in Concealed Weapon and Contraband Detection NIJ Standard-0602.02 Supersedes NIJ Standard-0602.01 dated September 2000 Supersedes NILECJ-STD-0602.00 dated October 1974 Nicholas G. Paulter, Jr. Electricity Division National Institute of Standards and Technology Gaithersburg, MD 20899 Prepared for: National Institute of Justice Office of Science and Technology Washington, DC 20531 November 2003 NCJ 200330 ---------------------------- National Institute of Justice Sarah V. Hart Director This standard was prepared for the National Institute of Justice, U.S. Department of Justice, by the Office of Law Enforcement Standards of the National Institute of Standards and Technology under Interagency Agreement 99-IJ-R-094, Project No. 02-002. The NIJ Standard-0602.02, "Hand-Held Metal Detectors for Use in Concealed Weapon and Contraband Detection," is a revision to and supersedes the NIJ Standard-0602.01 published in September 2000. The 2000 revision addressed concerns of the criminal justice and public safety communities for an updated performance standard based on current technologies and responded to recommendations from the Law Enforcement and Corrections Technology Advisory Council. This current revision responds to comments received from industry and the criminal justice and public safety communities on the 2000 revision. K.D. Rice of the Office of Law Enforcement Standards (OLES) of NIST and D.R. Larson of NIST are acknowledged for their comments and recommendations. ---------------------------- FOREWORD The Office of Law Enforcement Standards (OLES) of the National Institute of Standards and Technology (NIST) provides technical support to the National Institute of Justice (NIJ) program to support law enforcement and criminal justice in the United States. OLES's function is to develop standards and conduct research that will assist law enforcement and criminal justice agencies. OLES is (1) subjecting existing equipment to laboratory testing and evaluation, and (2) conducting research leading to the development of several series of documents, including national standards, user guides, and technical reports. This document covers research conducted by OLES under the sponsorship of NIJ. Additional reports as well as other documents are being issued under the OLES program in the areas of protective clothing and equipment, communications systems, emergency equipment, investigative aids, security systems, vehicles, weapons, and analytical techniques and standard reference materials used by the forensic community. Technical comments and suggestions about this guide are welcome and may be addressed to the Office of Law Enforcement Standards, National Institute of Standards and Technology, 100 Bureau Drive, Stop 8102, Gaithersburg, MD 20899-8102. Sarah V. Hart, Director National Institute of Justice ---------------------------- CONTENTS FOREWORD COMMONLY USED SYMBOLS AND ABBREVIATIONS INTRODUCTION 1.1 Purpose of the Standard 1.2 Definitions 2. REQUIREMENTS FOR ACCEPTANCE 2.1 Safety Specifications and Requirements 2.2 Electrical Requirements 2.3 Detection Performance Specifications 2.4 Operating Requirements 2.5 Mechanical Specifications and Requirements 2.6 Functional Requirements 2.7 Detector Holder 2.8 Quality Control and Assurance 2.9 Documentation 3. PERFORMANCE TESTING PROCEDURES 3.1 General Test Conditions 3.2 Detection Performance Tests 3.3 Alarm Indication Tests 3.4 Test for Operation Near a Metal Wall 3.5 Battery Life Test 3.6 Burn-In Test 3.7 Power Cycling Test 4. FIELD TESTING PROCEDURES 4.1 Large Object Size 4.2 Medium Object Size 4.3 Small Object Size 4.4 Very Small Object Size 5. TEST OBJECTS DESCRIPTION 5.1 Large Object Size Test Objects 5.2 Medium Object Size Test Objects 5.3 Small Object Size Test Objects 5.4 Very Small Object Size Test Objects 6. COMPLIANCE TEST REPORT FORM 7. REFERENCES FIGURES Figure 1. Diagram of two different hand-held metal detectors showing the detector plane and the detector axis Figure 2. Drawing of the detector holder and detector positioner showing attachment at the reference surface Figure 3. Diagram of the measurement coordinate system showing the measurement coordinate system axes, one measurement plane, the detector plane, and the reference surface, where the detector holder, containing a detector, is unmounted Figure 4. A schematic of the detector and the detector positioner, with detector in place, where the detector holder is properly located on the detector positioner; that is, where the z axis of the measurement coordinate system, the detector axis, and the reference axis are collinear; the detector holder and detector positioner are incontact at their reference surfaces; and the long axis of the detector is collinear with the x axis of the measurement coordinate system Figure 5. Mechanical drawing of the reference surface ---------------------------- COMMONLY USED SYMBOLS AND ABBREVIATIONS A--ampere ac--alternating current AM--amplitude modulation cd--candela cm--centimeter CP--chemically pure c/s--cycle per second d--day dB--decibel dc--direct current [degrees]C--degree Celsius [degrees]F--degree Fahrenheit dia--diameter emf--electromotive force eq--equation F--farad fc--footcandle fig.--figure FM--frequency modulation ft--foot ft/s--foot per second g--acceleration g--gram gr--grain H--henry h--hour hf--high frequency Hz--hertz (c/s) i.d.--inside diameter in--inch IR--infrared J--joule L-lambert L-liter lb--pound lbf--pound-force lbf in--pound-force inch lm--lumen ln--logarithm (base e) log--logarithm (base 10) M--molar m--meter min--minute mm--millimeter mph--miles per hour m/s--meter per second N--newton N m--newton meter nm--nanometer No.--number o.d.--outside diameter [omega]--ohm p.--page Pa--pascal pe--probable error pp.--pages ppm--parts per million qt--quart rad--radian rf--radio frequency rh--relative humidity s--second SD--standard deviation sec.--section SWR--standing wave ratio uhf--ultrahigh frequency UV--ultraviolet V--volt vhf--very high frequency W--watt [lambda]--wavelength wt--weight area = unit[2] (e.g., ft[2], in[2], etc.) ; volume=unit[3] (e.g., ft[3], m[3], etc.) PREFIXES d--deci (10[-1]) c--centi (10[-2]) m--milli (10[-3]) [mu]--micro (10[-6]) n--nano (10[-9]) p--pico (10[-12]) da--deka (10) h--hecto (10[2]) k--kilo (10[3]) M--mega (10[6]) G--giga (10[9]) T--tera (10[12]) COMMON CONVERSIONS (See ASTM E380) 0.30480 m = 1ft 25.4 mm = 1 in 0.4535924 kg = 1 lb 0.06479891g = 1gr 0.9463529 L = 1 qt 3600000 J = 1 kW hr 4.448222 N = 1 lbf 1.355818 J = 1 ft lbf 0.1129848 N m = 1 lbf in 14.59390 N/m = 1 lbf/ft 6894.757 Pa = 1 lbf/in[2] 1.609344 km/h = 1 mph Temperature: T [degrees]C = (T [degrees]F 32) x5/9 Temperature: T [degrees]F = (T [degrees]C 9/5) +32 ---------------------------- NIJ Standard-0602.02 NIJ STANDARD FOR HAND-HELD METAL DETECTORS FOR USE IN CONCEALED WEAPON AND CONTRABAND DETECTION 1. INTRODUCTION 1.1 Purpose of the Standard The purpose of this document is to establish performance requirements and testing methods for active hand-held metal detectors used to find metal weapons and/or metal contraband carried on a person and/or concealed by a nonmetal object. 1. 2 Definitions The definitions are provided to help the reader use and understand this document, which describes methods for evaluating active hand-held metal detectors used as weapons detectors. Terms that are defined here appear in italics in the remainder of this document. All measurement units used in this document are metric. Length units are abbreviated: meter (m), centimeter (cm), and millimeter (mm). Where useful, English units are indicated in parentheses immediately following the metric units, such as "2.54 cm (1 in)." 1.2.1 Active Detector An active detector is generally a device that generates energy for illuminating the target space. For the hand-held metal detector, the generated energy is in the form of a magnetic field. The interaction of this magnetic field with certain types of objects in the region around the detector and the ability to detect this interaction are the basis of operation for hand-held metal detectors. 1.2.2 Alarm Indication A signal to warn of the detection of a metal object. The indication can be visual and/or auditory. 1.2.2.1 Positive Alarm Indication The change in the alarm indication that corresponds to the detection of a metal object. Typically, the alarm indication is off until a metal object is detected. 1.2.2.2 Proportional Alarm Indication An alarm indication proportional to the size, proximity, orientation, and/or material of an object. 1.2.3 Alarm Indicator The device used to generate the alarm indication. This device can provide a visual, auditory, and/or vibratory indication. For a visual indication, the alarm generating device can be a light bulb, lamp, light emitting diode, etc. For an auditory indication, the alarm generating device can be a horn, siren, buzzer, or similar item. 1.2.4 Detection The discovery or finding of a metallic object. The detection of a metallic object is transmitted to the operator by some type of alarm indicator typically a visual or audible indicator. 1.2.5 Detector Axis An imaginary line passing through and perpendicular to the detector plane that is located within the detector plane such that the magnetic field around the detector axis has the maximum symmetry. The detector axis is labeled as the "z" axis. The location of the detector axis relative to the detector shape and geometry is specified by the manufacturer. See figure 1. 1.2.6 Detector Holder A nonconductive, nonmagnetic block that holds the hand-held metal detector for testing. The detector holder is supplied by the manufacturer and contains a reference surface that mates to the reference surface of the detector positioner. Figure 2 shows how the detector holder is used and section 2.7 provides specific requirements. 1.2.7 Detector Plane An imaginary plane (two-dimensional surface) that passes through the center of the sensor region of the hand-held metal detector, bisects the sensor region into two symmetric halves, and is parallel to the plane of the sensing element. The detector plane contains two orthogonal axes labeled as the "x" axis and as the "y" axis. See figure 1. 1.2.8 Detector Positioner A nonconductive, nonmagnetic device that fixes the position of the detector plane and detector axis with respect to the three-axes translation system. The detector positioner includes a reference surface for attaching the detector holder. The detector positioner also includes a surface for attachment to the three-axes translation system. 1.2.9 Detector Response The electrical signal generated by the sensor or sensor circuit of the detector that is caused by an object interacting with the magnetic field generated by the detector. The detector response is the basis on which an alarm indication is derived. 1.2.10 Measurement Coordinate System A mutually orthogonal three-dimensional Cartesian coordinate system referenced to the detector axis and the detector plane. The three axes are labeled "x," "y," and "z," where the z axis is parallel to the detector axis and the x axis and the y axis are in the detector plane. The orientation of the test objects and the direction of the magnetic field is referenced to the measurement coordinate system. See figure 3. 1.2.11 Measurement Plane An imaginary two-dimensional surface over which the hand-held metal detectors are tested. There may be more than one measurement plane. The measurement plane(s) is (are) referenced from the detector plane. See figure 4. 1.2.11.1 Large Object Size Measurement Plane The measurement plane at a test separation distance of 15 cm from the detector plane. 1.2.11.2 Medium Object Size Measurement Plane The measurement plane at a test separation distance of 7.5 cm from the detector plane. 1.2.11.3 Small Object Size Measurement Plane The measurement plane at a test separation distance of 5 cm from the detector plane. 1.2.11.4 Very Small Object Size Measurement Plane The measurement plane at a test separation distance of 3 cm from the detector plane. 1.2.12 Reference Axis An imaginary line that is perpendicular to and centered in the reference surface. See figure 4. 1.2.13 Reference Surface The planes located on the detector holder and detector positioner that are used to attach the detector holder and detector positioner See figure 2. 1.2.14 Object Size Classes A classification method based on the ability to detect metal objects of a minimum size. A detector may meet the requirements for one or all object size classes as defined below. 1.2.14.1 Large Object Size The ability to detect handguns concealed on an individual that are constructed of either ferromagnetic or nonferromagnetic metal. 1.2.14.2 Medium Object Size The ability to detect knives concealed on an individual that are constructed of either ferromagnetic or nonferromagnetic metal. Knives are defined for this purpose as having blade lengths exceeding 7.5 cm (3 in). 1.2.14.3 Small Object Size The ability to detect small weapons and contraband items concealed on an individual that are constructed of either ferromagnetic or nonferromagnetic metal. Small weapons and contraband items are defined as items that can be used to injure another person or to defeat security devices. 1.2.14.4 Very Small Object Size The ability to detect very small hard-to-find items that are concealed on an individual and considered a threat to officer and prisoner safety or that can be used to defeat security measures. These objects are constructed of either ferromagnetic or nonferromagnetic metal. 1.2.15 Test Object An item that is used to test the hand-held detection performance. The test object is an encased replica of a metallic item. This item is either a weapon, can be used as a weapon, or can be used to defeat security devices. The shape of the encasement is a parallelepiped. The encasement has up to nine orientation holes that allow the replica to be oriented with respect to the measurement coordinate system. These nine orientation holes are distributed on no more than three surfaces of the test object. Each of these surfaces has no more than three orientation holes, and one of the orientation holes is used as a center of rotation. 1.2.15.1 Large Object Size Test Objects Test objects that are used to test the large object size detection performance of hand-held metal detectors used as weapon detectors. Mechanical drawings of large object size test objects are provided in section 5.1. 1.2.15.2 Medium Object Size Test Objects Test objects that are used to test the medium object size detection performance of hand-held metal detectors used as weapon detectors. Mechanical drawings of medium object size test objects are provided in section 5.2. 1.2.15.3 Small Object Size Test Objects Test objects that are used to test the small object size detection performance of hand-held metal detectors used as weapon detectors. Mechanical drawings of the small object size test objects are provided in section 5.3. 1.2.15.4 Very Small Object Size Test Objects Test objects that are used to test the very small object size detection performance of hand-held metal detectors used as weapon detectors. Mechanical drawings of the very small object size test objects are provided in section 5.4. 1.2.16 Test Object Axes The three mutually orthogonal axes of the test object that are referenced to and have a one-to-one correspondence with the axes of the measurement coordinate system. 1.2.17 Test Separation Distance The distance between the measurement plane (s) and the detector plane or as otherwise specified. The test separation distances are 3 cm, 5 cm, 7.5 cm, and 15 cm. See figure 4. 1.2.18 Three-Axes Positioning System Also known as a Cartesian robot, the three-axes positioning system provides three mutually orthogonal directions of linear translation. The three-axes positioning system is used to place the test objects in the magnetic field of the detector. 2. REQUIREMENTS FOR ACCEPTANCE The detector shall meet the requirements and specifications stated in this section. Reports shall be provided on the Compliance Test Report forms mentioned in section 6. 2.1 Safety Specifications and Requirements 2.1.1 Electrical The detector shall comply with UL 60950, Safety for Information Technology Equipment, if the potential difference between any two points within the detector is greater than 30 V rms (42.4 V peak-to-peak) for alternating currents (ac) or greater than 60 V referenced to ground for direct currents (dc). 2.1.2 Mechanical The detector shall not expose (1) any sharp corners or edges that can puncture, cut, or tear the skin or clothing or injure persons coming in contact with the detector; (2) external wires and cables; or (3) loose covers and cowlings. The minimum exposed radius of curvature for corners and edges shall be 1 mm (0.04 in). 2.1.3 Exposure The level of the electromagnetic field generated by the detector shall be less than the exposure limits specified in IEEE C95.1-1991, as amended. 2.1.4 Personal Medical Electronic Devices The magnetic fields produced by the detector shall not generate voltages across the leads of the test probe specified in Safety Code, Recommended Safety Procedures for the Selection, Installation and Use of Active Metal Detectors, Radiation Protection Bureau, Canadian Minister of National Health and Welfare (the Code) that exceed the maximum permitted probe output specified in the Code when tested in accordance with the Code. 2.2 Electrical Requirements 2.2.1 Battery Condition The manufacturer shall provide a visual or audible indicator to alert the operator of the battery condition as described in section 2.6.3. 2.2.2 Minimum Battery Life The detector must be designed so that the battery life is at least 40 h as tested in accordance with section 3.5. 2.3 Detection Performance Specifications The detection performance specifications shall be tested using the detection sensitivity setting that is specified by the manufacturer to be appropriate for each object size class of the detector that is to be tested. The detector need only to qualify for the smallest object size class specified by the manufacturer; qualification to larger object size classes will be assumed. 2.3.1 Detection Sensitivity The detector shall alarm for each test object of the appropriate object size class positioned in the appropriate measurement plane for each allowed orientation of the test object axes with respect to the measurement coordinate system for the test object moving at a speed of 1.0 m/s +/- 0.05 m/s and as tested in accordance with section 3.2.3. (The appropriate measurement planes are the large object size, medium object size, small object size, and very small object size measurement planes as defined in sec. 1.2.11). 2.3.2 Speed The detector shall provide a positive alarm indication for each test object of the appropriate object size class positioned in the appropriate measurement plane for each allowed orientation of the test object axes with respect to the measurement coordinate system for the test object moving at the following speeds: 0.05 m/s +/- 0.01 m/s, 0.5 m/s +/- 0.01 m/s, 1.0 m/s +/- 0.01 m/s, and 2.0 m/s +/- 0.01 m/s as tested in accordance with section 3.2.4, and the results shall be recorded. 2.3.3 Repeatability The detector shall provide a positive alarm indication without failure for each test object of the appropriate object size class positioned in the appropriate measurement plane for each allowed orientation of the test object axes with respect to the measurement coordinate system for the test object moving at a speed of 1.0 m/s +/- 0.05 m/s for 50 consecutive trials under the following conditions: a. The delay between subsequent trials of a given test object shall be no more than 10 s. b. The detector sensitivity shall not be readjusted between trials of a given test object or between trials of the test objects of a given object size class. The repeatability test shall be performed in accordance with section 3.2.4, and the results shall be recorded. The results of this test can also be called the probability of detection, p[d], with a required p[d] of 1.00 (or 100 %). 2.4 Operating Requirements 2.4.1 Operator Controls Only those controls indicated here shall be accessible by the operator. Other controls and adjustments that affect the detector performance shall be inaccessible to the operator. 2.4.1.1 Detector Sensitivity Programming (Optional) If provided, the detector sensitivity shall be controlled by a discretely adjustable switch. The switch shall be located such that it is readily accessible by the operator or, upon request, to be within an enclosed area and inaccessible to the operator. 2.4.1.2 Power On/Off Switch The detector shall have a power on/off switch. 2.4.1.3 Audible Alarm On/Off Switch The detector shall have a means for selectively disabling the audible alarm. 2.4.2 Background Null/Automatic Adjust Feature On/Off Switch If any feature exists on the detector to automatically adjust for or null the detection signal caused by a large metal background, the detector shall have an on/off switch for this feature. 2.4.3 Interference 2.4.3.1 Electromagnetic 2.4.3.1.1 Emission The detector, when adjusted to meet the requirements of section 2.3.3, shall meet the requirements of EN 50081-1, as amended, if applicable. 2.4.3.1.2 Susceptibility/Immunity 2.4.3.1.2.1 General Immunity Requirements The detector, when adjusted to meet the requirements of section 2.3.3, shall not provide a positive alarm indication when tested in accordance with EN 50082-1, as amended, if applicable. 2.4.3.1.2.2 Radiated Magnetic Field The detector, when adjusted to meet the requirements of section 2.3.3, shall not provide a positive alarm indication when tested in accordance with MIL- STD-461E, Method RS101, as amended, to the limits for Navy applications. 2.4.3.2 Metal The detector shall not produce a positive alarm indication when operated near metal walls, as tested in accordance with section 3.4, but shall produce a positive alarm indication for each appropriate test object of the appropriate object size class positioned in the appropriate measurement plane for each allowed orientation of the test object axes with respect to the measurement coordinate system for the test object moving at a speed of 1.0 m/s +/- 0.05 m/s as tested according to section 3.2.4. 2.4.3.3 Body The detector shall not produce a positive alarm indication when operated at a distance from the body equal to the appropriate test separation distance, as tested in accordance with section 3.2.5, but shall produce a positive alarm indication for each test object of the appropriate object size class positioned in the appropriate measurement plane for each allowed orientation of the test object axes with respect to the measurement coordinate system for the test object moving at a speed of 1.0 m/s +/- 0.05 m/s as tested according to section 3.2.4. The test separation distances shall be 15 cm for test objects of the large object size class, 7.5 cm for test objects of the medium object size class, 5 cm for test objects of the small object size class, and 3 cm for test objects of the very small object size class. 2.4.4 Environmental Ranges and Conditions The detector or all of its components and their interconnections shall meet all of the requirements listed in this section. The requirements of section 2.1 and section 2.5 shall not be affected by the tests described in this section. The requirements given in this section shall be applied appropriately for either indoor or indoor/outdoor detector models. The requirements of this section shall be exhibited by no less than the first production unit for each unique detector model and for any physical modifications to that model. The tests listed in section 2.4.4 shall be performed on the same unit. The detector, if tested for any of the tests listed in section 2.4.4, shall exhibit no observable changes in the detection performance specification given in section 2.3.3. 2.4.4.1 Temperature Stability and Range 2.4.4.1.1 Indoor The detector shall operate over the ambient temperature range of at least 0 [degrees]C to 46 [degrees]C (32 [degrees]F to 115 [degrees]F). The detector shall be tested in accordance with MIL-STD-810F Method 501.4, Procedure II, at 46 [degrees]C +/- 3 [degrees]C after being exposed to that temperature continuously for 24 h +/- 1 h. The detector then shall be cooled to 0 [degrees]C +/- 3 [degrees]C within 4 h +/- 0.5 h and tested in accordance with MIL-STD-810F Method 502.4, Procedure II, at 0 [degrees]C +/- 3 [degrees]C after being exposed to that temperature continuously for 24 h +/- 1 h. 2.4.4.1.2 Indoor/Outdoor The detector shall operate over the ambient temperature range of at least -37 [degrees]C to 65 [degrees]C (-35 [degrees]F to 149 [degrees]F). The detector shall be tested in accordance with MIL-STD-810F Method 501.4, Procedure II, at 65 [degrees]C +/- 3 [degrees]C after being exposed to that temperature continuously for 24 h +/- 1 h. The detector then shall be cooled to -37 [degrees]C +/- 3 [degrees]C within 4 h +/- 0.5 h and tested in accordance with MIL-STD-810F Method 502.4, Procedure II, at -37 [degrees]C +/- 3 [degrees]C after being exposed to that temperature continuously for 24 h +/- 1 h. 2.4.4.2 Relative Humidity Stability and Range The detector shall be tested in accordance with the requirements of MIL-STD- 810F Method 507.4, as amended. 2.4.4.3 Salt Fog, Indoor/Outdoor Only The detector shall be tested in accordance with the requirements of MIL-STD- 810F Method 509.4, as amended. 2.4.4.4 Environmental Protection The detector shall meet or exceed the requirements for compliance with IEC 60529 classification IP54. 2.4.4.5 Solar Radiation (Sunshine), Indoor/Outdoor Only The detector shall be tested in accordance with and meet the requirements of MIL-STD-810F Method 505.4, Procedure 1, as amended. 2.5 Mechanical Specifications and Requirements 2.5.1 Dimensions and Weight The detector should be capable of being gripped by a single hand, shall weigh less than 1 kg (2.2 lb), and be designed to reduce operator fatigue during long-term use. 2.5.2 Durability/Ruggedness The detector or all of its components and their interconnections shall meet the requirements of the following standards. The requirements of section 2.1 and section 2.4 shall not be affected by the tests described in this section. All tests listed in section 2.5.2 shall be performed on the same unit. The detector, if tested for any of the tests listed in section 2.5.2.1, shall exhibit no observable changes in the detection performance specification given in section 2.3.3. 2.5.2.1 Shock The detector shall be tested in accordance with the requirements of IEC 68-2- 27 1987, as amended, using the half-sine pulse shape with a nominal peak acceleration of 30 g (300 m/s[2]) and a nominal pulse duration of 6 ms. 2.5.2.2 Bump The detector shall be tested in accordance with the requirements of IEC 68-2- 29 1987, as amended, using 100 bumps each with a nominal peak acceleration of 40 g (400 m/s[2]) and a nominal pulse duration of 6 ms. 2.5.2.3 Free Fall The detector shall be tested in accordance with the requirements of IEC 68-2- 32 Procedure 1, 1975, as amended, for each direction of the detector axes and a fall height of 1 m. 2.5.2.4 Pressure Resistance The detector shall be capable of withstanding the force of 600 N (135 lb) over any 1 cm x 1 cm (0.4 in x 0.4 in) area on the detector for a sustained period of 1 min. 2.6 Functional Requirements 2.6.1 Audible Alarms All audible indicators (other than an earphone) shall produce an alarm-state sound pressure level 0.8 m +/- 0.08 m from the detector of 85 dB[SPL] +/- 5 dB[SPL] measured in accordance with section 3.3.2. For status indicators, the audible alarm shall be a two-state audible alarm: active (alarm state) and inactive (nonalarm state). For metal object warning, the audible alarm shall be a frequency-proportional audible alarm or, optionally, a two-state audible alarm. 2.6.1.1 Earphone Jack (Optional) If an earphone jack is supplied with the hand-held metal detector, the earphone shall disable the audible alarm indicator when the earphone is plugged into the earphone jack. 2.6.1.2 Alarm Indicator for Metal Object Detection The detector shall have either a frequency-proportional alarm indicator (see sec. 2.6.1.2.1) or a two-state alarm indicator (see sec. 2.6.1.2.2). 2.6.1.2.1 Frequency-Proportional Alarm Indicator for Metal Object Detection The frequency-proportional alarm indicator shall provide an audible alarm indication with an audio frequency output that is continuously proportional to the detection signal. The frequency-proportional alarm indication shall have a quiescent state frequency drift rate, measured in accordance with section 3.3.3, of not more than 5 Hz/s. The proportional alarm indication shall vary by at least 2000 Hz within the frequency range of 500 Hz to 4000 Hz for objects varying in size from the smallest test objects of the appropriate object size class to the metal test panel described in section 3.4.1. 2.6.1.2.2 Two-State Alarm Indicator for Metal Object Detection The two-state alarm indicator shall provide a two-state audible alarm indication to alert the operator about the presence of a metal object. The two-state alarm indicator shall produce no sound in the nonalarm state and shall produce an audio frequency alarm within the range of 500 Hz to 4000 Hz with a -3 dB frequency bandwidth of less than 1 % of the selected operating frequency and a frequency drift of less than 5 Hz/s and less than 1 % of the selected operating frequency over any 2-h period. 2.6.2 Visual Indicators Any visible alarm indication shall be readily perceptible when tested in accordance with section 3.3.4. The visual alarm indicators shall be a two-state visual alarm: active (illuminating) and inactive (nonilluminating). 2.6.2.1 Metal Object Detection The detector shall have a visual alarm indicating the presence of a metal object in the target space. The alarm state for the metal-object-detection visual alarm indicator shall be active (illuminating), and the nonalarm state shall be inactive (nonilluminating). The metal-object-detection visual alarm indicator shall be distinct from any other visual alarm indicators. 2.6.3 Battery Condition Indicator The detector shall have a visual or audible alarm indicating the condition of the battery and shall be activated if the battery condition drops to a level that can cause a degradation of the detection performance required by this standard. 2.6.4 Interchangeability Any model detector manufactured by the same manufacturer shall be compatible with previous revisions of the same model (backwardly compatible). In particular, the components shall be backwardly compatible. 2.7 Detector Holder The manufacturer shall provide with each detector, if requested, a holder for mounting the detector on the reference surface (see fig. 5) of the measurement system (see figs. 2 and 3). The detector holder shall comply with section 2.1.2 and shall meet the following specifications: a. Relative permeability =1. 0 +/- 0.001. b. Electrical conductivity <10[-8] Siemens/m. c. Mass less than or equal to 2 kg (4.5 lb). d. Surface flatness +/- 0.5 mm (0.041 in). e. Firmly holds the detector. f. Mates with the reference surface. g. Fastener holes align with each of the four 1/4-20 fastener holes of the reference surface (see figs. 2, 3, and 5). h. Holds the detector so that the detector axis and reference axis are collinear. i. Holds the detector so that the longest axis of the detector that is parallel to the detector plane is collinear with the x axis of the measurement coordinate system. j. Holds the detector so that the detector plane is 10 cm +/- 0.1 cm from the reference surface. k. The top surface should be located less than 2.5 cm from the detector plane. If the detector is of such shape and geometry that access to the measurement plane at a test separation distance of 2.5 cm is not possible, then the test separation distance for the closest possible measurement plane shall be reported. l. Holds the detector such that no part of the detector is above the measurement plane at a test separation distance of 2.5 cm. 2.8 Quality Control and Assurance 2.8.1 Quality Systems The manufacturer shall meet the requirements of ISO 9001:2000, as amended. 2.8.2 Testing and Calibration Laboratories Laboratories performing testing and calibration of the detector and/or its components shall meet the requirements of ISO 17025, as amended. 2.8.3 Measurement Equipment and Processes All measurement equipment and processes shall meet the requirements of ISO 10012-1, as amended, and ISO 10012-2, as amended. 2.8.4 Burn-In Power-on dynamic burn-in testing for a set of metal detectors of the same model is required in accordance with section 3.6. The set shall consist of m detectors of the same type and model selected using simple random sampling methods and tested without replacement where m = 0.1 Mk[m]/0.1 k[m] + 0.01 M. M is the number of the manufactured detectors of the same model, and k [m] is the coverage factor for the 99 % confidence interval. (See table B.1 of B.N. Taylor and C.E. Kuyatt, NIST Technical Note 1297, Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, U.S. Government Printing Office, Washington, DC, 1994.) The manufacturer shall provide the test results of this randomly selected set of the same type and model detectors. 2.8.5 Power Cycling Power cycling testing for a set of metal detectors of the same model is required in accordance with section 3.7. The set shall consist of m detectors of the same type and model selected using simple random sampling methods and tested without replacement where m = 0.1 Mk[m]/0.1 k[m] + 0.01 M. M is the number of the manufactured detectors of the same model and k[m] is the coverage factor for the 99 % confidence interval. (See Table B.1 of B.N. Taylor and C.E. Kuyatt, NIST Technical Note 1297, Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, U.S. Government Printing Office, Washington, DC, 1994.) The manufacturer shall provide the test results of this randomly selected set of the same type and model detectors. 2.9 Documentation The manufacturer shall provide the following list of deliverable items with each detector unless otherwise indicated. 2.9.1 Operating Instructions An operator 's manual shall be supplied by the manufacturer or distributor with each detector and shall contain at least the following information: a. The purpose of the detector. b. A description of operator controls. c. A list of operating features. d. A description of detection principles and detector capabilities. e. A block diagram showing the major internal functional components. f. An exposure warning that states, "This Device May Affect Personal Medical Electronic Devices" until such time that the Food and Drug Administration or some other competent Federal agency requires a different warning or has determined that no such warning is necessary. 2.9.2 Operator Training Instructions and Videotape or CD-ROM A training package shall be supplied upon request that will provide operators with the information necessary to acquire the technical and operational skills required to conduct effective screening with the detector. The training package shall include an audio/visual videotape or CD-ROM and an operator 's manual. For additional guidance in formulating the operator training package, review A Users ' Guide for Hand--Held and Walk-Through Metal Weapon Detectors (National Institute of Justice, NIJ Guide 600-00, 2001). The manufacturer shall have demonstrated the effectiveness of the training material when 50 % of the test group receiving the training understands the operation of the detector, passes a written test, and operates the detector successfully. The test group shall consist of at least 10 people with only a high school education. 2.9.3 Technical Manual A technical manual that contains all of the information that could be required by a technician to troubleshoot, maintain, and repair the equipment to the component level shall be provided upon request. 2.9.4 Technical Training Manual and Videotape or CD-ROM A self-study training package shall be provided upon request for use by site maintenance technicians. The training package must consist of an audio/visual videotape or CD-ROM and a technical manual that provides detailed explanations of circuit theory and maintenance procedures. 2.9.5 Technical Specifications The manufacturer shall provide, upon request, a detailed listing of all relevant specifications of the detector. This list shall include at a minimum: a. Detector object size class (as defined in sec. 1.2.14). b. Mechanical drawings of the detector with dimensions in metric units. c. Mass of the detector. d. Allowable range of ac line power supply voltage. e. Battery type, quantity, and life. f. Maximum magnetic field strength that can be found on the detector surface. g. If applicable, operating frequency and, if applicable, modulation parameters. h. If applicable, pulse repetition rate, pulse duration, and pulse transition duration. i. Operating ambient temperature range. 2.9.6 Certification of Test, Inspection, and Conformance The manufacturer shall provide, upon request, a certification of all mandatory tests; test procedures; testing laboratories; compliance to required standards; a record of the test results for the detector; and the identities of all the companies, laboratories, and/or organizations conducting the tests. 2.9.7 Suggested Maintenance Schedule The manufacturer shall provide a preventive maintenance schedule and a detailed list of the technical skills, computer hardware, and software tools required. 2.9.8 Installation Instructions The manufacturer shall provide instructions for battery installation and specify the type and quantity of batteries required. 3. PERFORMANCE TESTING PROCEDURES The detector shall meet the detection performance requirements for each object size class in which it is required to operate. The detection performance shall be evaluated by the test methods described in this section. The manufacturer shall record and provide the test results on the report forms mentioned in section 6 of this randomly selected set of same type and model detectors. 3.1 General Test Conditions 3.1.1 Test Location The distance between any metal object other than a test object and the closest part of the detector shall be greater than 0.8 m (31 in). 3.1.2 Environment At the time of the tests, the ambient temperature shall be in the range specified in section 2.4.4.1 for the appropriate application (indoor or indoor/outdoor); the relative humidity shall be noncondensing. 3.1.3 Preparations New batteries of the type listed in the operator 's manual shall be installed at the beginning of the tests and as instructed in any test method. Any setup or calibration adjustments specified in the operator 's manual shall be performed if required. 3.2 Detection Performance Tests 3.2.1 Object Size Classes If the detector can be adjusted to provide an alarm indication for more than one object size class, the detection performance test shall be performed for each object size class. The detection performance shall be evaluated by the test methods described in this section. The distinction in testing between the different object size classes is the difference in the test separation distance of the measurement plane and the test objects. 3.2.2 Equipment 3.2.2.1 Test Objects Test objects shall be as described in section 5. There are up to three orientation holes on up to three surfaces of the test object (encased replica of a threat item). The tapped hole on each surface of the test objects is labeled with an "A" ((see mechanical drawings in sec. 5 showing the encased test object) and is the center of rotation of the different orientations. The test objects shall be oriented such that the orienting holes being used are facing the three-axes positioning system as the test objects pass by the detector and that the hole labeled "A" is below the other orientation hole being used. The measurement plane shall pass through the test object at the point labeled "A" and be parallel to the bottom surface of the test object. If the detector is of such shape and geometry that access to the measurement plane at a test separation distance of 3 cm is not possible, then the test separation distance for the closest possible measurement plane shall be reported. Labeling for the test object orientation shall use two characters: the first character indicates in which quadrant of the mechanical drawing the specified orientation can be found, and the second character indicates the position of the unused hole relative to the hole labeled "A." The quadrant designations are given as follows: a. "1" indicates bottom left. b. "2" indicates bottom right. c. "3" indicates top left. d. "4" indicates top right. Not all quadrants are used. For the second character, "L" indicates that the unused hole is to the left of the hole labeled "A," and "R" indicates that the unused hole is to the right of the hole labeled "A." 3.2.2.2 Three-Axes Positioning System The three-axes positioning system shall meet the following requirements: a. Displacement, x and y axes: greater than or equal to 1 m. b. Displacement, z axis: greater than or equal to 2 m. c. Position accuracy, each axis: 1 mm. d. Position repeatability, each axis: 1 mm. e. Maximum slew speed, y axis: greater than or equal to 2 m/s. 3.2.2.3 Microphone (Audible Alarm Indicators) The microphone is the audible alarm indication detector. It shall be used to detect an audible positive alarm indication, be capable of detecting the audible alarm indication as described in section 2.6.1, and provide an analog output that can be interfaced to the computer controller (see sec. 3.2.2.6). 3.2.2.4 Light Detector (Visible Alarm Indicators) The light detector is the visible alarm indication detector. It shall be used to detect a visible positive alarm indication, be capable of being attached directly to the visual alarm indicator, and provide an analog electrical output that can be interfaced to the computer controller (see sec. 3.2.2.6). 3.2.2.5 Detector Positioner The detector positioner is a nonmagnetic, nonconductive device that provides a surface on which to securely attach the detector holder and that places the detector at a fixed location in the measurement coordinate system relative to the three-ax es positioning system. A diagram of the detector holder showing the reference axis, reference surface, and x, y, and z measurement coordinate system axes is given in figure 4. A detailed mechanical drawing of the reference surface is provided in figure 5. 3.2.2.6 Computer Controller The computer controller shall have installed and operational all necessary hardware and software for providing instrument control and data acquisition. 3.2.3 Detection Sensitivity 3.2.3.1 Initial Procedures Ensure that the alarm indication detector and positioning system are connected to the computer controller. Turn on the alarm indication detector, computer controller, and positioning system and verify proper operation of the measurement system. Ensure that the hand-held metal detector is securely held by the detector holder and fasten the detector holder to the detector positioner. Attach the test object with the proper orientation to the positioning system. Turn on the hand-held metal detector and ensure that its output is functioning properly by noting a change in the alarm indication detector output as a metal object is brought near the hand-held metal detector. Ensure that the test object does not hit any objects while in motion. 3.2.3.2 Performing the Measurement Set the computer program to perform an x-y scan in the specified measurement plane at the specified speed. Set the x-axis position to -10 cm +/- 0.1 cm relative to the detector axis and scan the y axis. Record any positive alarm indication using the alarm indication detector as the y-axis scan is being performed. Increment the x-axis position by 2 cm +/- 0.1 cm and perform a y-axis scan. Repeat the x-axis increment and y-axis scan until the x-axis position is approximately 10 cm +/- 0.1 cm. The center for the y-axis scans shall be the detector axis, and the scans shall each be 20 cm +/- 0.1 cm long. 3.2.4 Speed 3.2.4.1 Initial Procedures Ensure that the alarm indication detector and three-axes positioning system are connected to the computer controller. Turn on the alarm indication detector, computer controller, and three-axes positioning system and verify proper operation of the measurement system. Ensure that the hand-held metal detector is securely held by the detector holder and fasten the detector holder to the detector positioner. Attach the test object with the proper orientation to the three-axes positioning system. Turn on the hand-held metal detector and ensure that the detector output is functioning properly by noting a change in the alarm indication detector output as a metal object is brought near the hand-held metal detector. Ensure that the test object does not hit any objects while in motion. 3.2.4.2 Performing the Measurement Set the computer program to perform a y-axis scan passing through the detector axis in the appropriate measurement plane at the specified speed. Record any positive alarm indication with the alarm indication detector as the y-axis scan is being performed. The center of the y-axis scan shall be the detector axis in the appropriate measurement plane, and the y-axis scan shall be 20 cm +/- 0.1 cm long. 3.2.5 Body Interference 3.2.5.1 Initial Procedures Select a person (the tester), whose hand and wrist are void of any metal objects, to hold the detector. The tester shall hold the detector such that the detector plane is parallel to the palm of the tester, the palm of the tester shall face the detector, and the arms of the tester shall extend fully away from the body. Turn on the alarm indication detector and the hand-held metal detector and ensure that the hand-held metal detector output is functioning properly by noting a change in the alarm indication detector output as a metal object is brought near the hand-held metal detector. 3.2.5.2 Performing the Measurement Position the hand-held metal detector at the appropriate test separation distance from the palm of the tester and note any positive alarm indication. 3.3 Alarm Indication Tests 3.3.1 Equipment 3.3.1.1 Sound Level Meter The sound pressure level meter shall comply with ANSI S1.4, 1971, for type 3, A-weighting, reference pressure 20 uPa. 3.3.1.2 Audio Frequency Measurement System The system for measuring the fundamental audio frequency of an audible alarm indication shall be capable of measuring a frequency difference with an accuracy of 1 Hz and be capable of providing a new measurement within 4 s after a change in frequency. 3.3.1.3 Illumination Meter The illumination meter shall be capable of measuring light levels of 25 lm/m[2] and 10 000 lm/m[2] with an error of not more than 10 %. The integrated spectral response shall be within 10 % of the Commission Internationale de l 'Eclairage (CIE, the International Commission on Illumination) photopic curve. 3.3.2 Sound Pressure Level Test Perform the test in an anechoic chamber or at an outdoor location at least 6 m from any large object, where the ambient sound pressure level at the time of the test is not more than 53 dB[SPL]. Position the sound pressure level meter microphone 0. 80 m +/- 0.02 m from the detector. Measure the sound pressure level with the detector power applied and the alarm indicator in the nonalarm state. Then position the appropriate test object at a test separation distance of approximately 5 cm to produce an alarm, and again measure the sound pressure level. 3.3.3 Frequency Stability Test After the detector has been off for at least 5 min, turn the detector on and complete any operator adjustments specified in the operator 's manual within 10 s. Measure the frequency at 15 s +/- 1 s and again at 45 s +/- 1 s after the detector has been turned on. Compute the average frequency drift rate by taking the difference between the measured frequencies and dividing by 30 s. Perform the procedure three more times and compute the mean of the average frequency drift rates. 3.3.4 Visible Alarm Indicator Test Position the detector with its alarm indicator 0.80 m +/- 0.02 m from the eyes, at a test site where the ambient illumination is 10 000 lm/m[2] +/- 1000 lm/m[2]. After waiting at least 3 min to allow for eye accommodation, turn on the detector and move a metal object near the detector to cause an alarm. Observe the indication. Repeat the test at a test site where the ambient illumination is 25 lm/m[2] +/- 2.5 lm/m[2]. 3.4 Test for Operation Near a Metal Wall 3.4.1 Metal Test Panel The metal test panel shall be cold-finished sheet carbon steel UNS G10150 to G10200, 1 m +/- 0.1 m by 1 m +/- 0.1 m by 0.75 mm +/- 0.13 mm thick. The panel shall be mounted or supported in a manner that keeps the panel flat. 3.4.2 Procedure Position the detector with its detector plane parallel to and 0.5 m +/- 0.01 m from the plane of the test panel and with the detector axis centered with respect to the test panel. Turn on the detector and adjust its controls as specified in the operator 's manual. Note the alarm indicator response. 3.5 Battery Life Test Install in the detector new or fully charged batteries of the type specified by the manufacturer. Turn the detector on and leave it on for a continuous 40 h +/- 1 h period. Within 1 h from the end of this period and without changing the batteries, test the detector in accordance with section 2.3.3 for the test object of the appropriate object size class, its material, and its orientation (see sec. 3.2.2.1) given below: a. Large object size: Handgun: material, zinc; orientation, 3L. b. Medium object size: Knife: material, aluminum; orientation, 3L. c. Small object size: Stainless steel knife: orientation, 3L. d. Very small object size: Razor blade: orientation, 3L. 3.6 Burn-In Test Turn the detector on (such that it is ready to detect a metal object) for a period of 160 h +/- 5 h. Replace the battery once every 40 h +/- 1 h, if necessary. Without turning the detector off, test the detector in accordance with section 2.3.3 for the test object of the appropriate object size class, its material, and its orientation (see sec. 3.2.2.1) given below: a. Large object size: Handgun: material, zinc; orientation, 3L. b. Medium object size: Knife: material, aluminum; orientation, 3L. c. Small object size: Stainless steel knife: orientation, 3L. d. Very small object size: Razor blade: orientation, 3L. 3.7 Power Cycling Test Turn the detector power on and off 100 times +/- 2 times within 300 s +/- 30 s and immediately (within 60 s) test the detector in accordance with section 2.3.3 for the test object of the appropriate object size class, its material, and its orientation (see sec. 3.2.2.1) given below: a. Large object size: Handgun: material, zinc; orientation, 3L. b. Medium object size: Knife: material, aluminum; orientation, 3L. c. Small object size: Stainless steel knife: orientation, 3L. d. Very small object size: Razor blade: orientation, 3L. 4. FIELD TESTING PROCEDURES 4.1 Large Object Size The detector shall provide a positive alarm indication when passed approximately 15 cm (6 in) from the large object size test objects described in section 5.1. Repeat this test three times at pass-by speeds ranging from approximately 0.5 m/s to approximately 1.5 m/s to ensure proper detector performance. 4.2 Medium Object Size The detector shall provide a positive alarm indication when passed approximately 7.5 cm (3 in) from the medium object size test objects described in section 5.2. Repeat this test three times at pass-by speeds ranging from approximately 0.5 m/s to approximately 1.5 m/s to ensure proper detector performance. 4.3 Small Object Size The detector shall provide a positive alarm indication when passed approximately 5 cm (2 in) from the small object size test objects described in section 5.3. Repeat this test three times at pass-by speeds ranging from approximately 0.5 m/s to approximately 1.5 m/s to ensure proper detector performance. 4.4 Very Small Object Size The detector shall provide a positive alarm indication when passed approximately 3 cm (1.2 in) from the very small object size test objects described in section 5.4. Repeat this test three times at pass-by speeds ranging from approximately 0.5 m/s to approximately 1.5 m/s to ensure proper detector performance. 5. TEST OBJECTS DESCRIPTION This section contains mechanical drawings of the test objects. The test objects are encased replicas of threat items. All dimensions in the mechanical drawings are given in units of millimeters (mm). 5.1 Large Object Size Test Objects The following mechanical drawings are of replicas of the large object size item that is considered a threat to an officer, a prisoner, an inmate, and public safety. The large object size threat item is a handgun. The mechanical drawings are arranged in the following order: the replica of the handgun and the location of the replica within the encasement. Three replicas are made and encased, one from each of the materials indicated in the drawings. 5.2 Medium Object Size Test Objects The following mechanical drawings are of the replicas of the medium object size item that is considered a threat to an officer, a prisoner, an inmate, and public safety. The medium object size threat item is a knife. The mechanical drawings are arranged in the following order: the replica of the knife and the location of the replica within the encasement. Two replicas are made and encased, one from each of the materials indicated in the drawings. 5.3 Small Object Size Test Objects The following mechanical drawings are replicas of the small object size items that are considered a threat to officer and prisoner safety and that can be used to defeat security measures. These items are replicas of a handcuff key, a nonferromagnetic stainless steel knife, and a 22-caliber Long Rifle cartridge. 5.3.1 Handcuff Key This section contains mechanical drawings of the replica of a handcuff key, a small object size test object. The mechanical drawings are arranged in the following order: the replica of the handcuff key and the location of the replica within the encasement. 5.3.2 Nonferromagnetic Stainless Steel Knife This section contains mechanical drawings of the replica of a nonferromagnetic stainless steel knife, a small object size test object. The mechanical drawings are arranged in the following order: the replica of the knife and the location of the replica within the encasement. 5.3.3 Firearm Cartridge (22-Caliber Long Rifle) This section contains mechanical drawings of the replica of a firearm cartridge, a small object size test object. The mechanical drawings are arranged in the following order: the cartridge assembly, the bullet portion of the replica, the case portion of the replica, and the location of the replica within the encasement. 5.4 Very Small Object Size Test Objects 5.4.1 Pen Refill This section contains mechanical drawings of the replica of a pen refill, a very small object size test object. The mechanical drawings are arranged in the following order: the replica of the pen refill and the location of the replica within the encasement. 5.4.2 Disposable Razor Blade This section contains mechanical drawings of the replica of a disposable razor blade, a very small object size test object. The mechanical drawings are arranged in the following order: the replica of the razor blade and the location of the replica within the encasement. 5.4.3 Hypodermic Needle, Disposable Syringe (Optional) A mechanical drawing is not included because this is an optional small object size test object. It is suggested that the actual object be used for this optional small object size test object. This optional test object should be a stainless steel hypodermic needle with ferrule, typically found on disposable insulin syringes. 6. COMPLIANCE TEST REPORT FORM The Compliance Test Report (CTR) form shall be used in conjunction with NIJ Standard 0602.-02, Hand-Held Metal Detectors for Use in Concealed Weapon and Contraband Detection, and shall become a part of the official records of the compliance testing of each metal detector model submitted for testing. All sections of the form shall be completed. An electronic file of the CTR form is available from the NLECTC Compliance Testing Office, National Law Enforcement and Corrections Technology Center-National (NLECTC-National). Requests for this file can be sent to: NLECTC-National, Attn: Metal Detector Testing Program, P.O. Box 1160, Rockville, MD 20849-1160; or by e-mail to asknlectc@nlectc.org. 7. REFERENCES The following normative documents contain provisions, which through reference in this text, constitute provisions of this Standards Publication. By reference herein, these publications are adopted, in whole or in part, as indicated. ANSI S1.4, 1971, American National Standards Institute, Specifications for General Purpose Sound Level Meters. EN 50081-1 1992, European Standard, Electromagnetic Compatibility - Generic Emission Standard, Part 1: Residential, Commercial, and Light Industry. EN 50082-1 1998, European Standard, Electromagnetic Compatibility - Generic Immunity Standard, Part 1: Residential, Commercial, and Light Industry. IEC 68-2-27 1987, International Electrotechnical Commission, Basic Environmental Testing Procedures, Part 2: Tests - Test Ea and Guidance: Shock. IEC 68-2-29 1987, International Electrotechnical Commission, Basic Environmental Testing Procedures, Part 2: Tests - Test Eb and Guidance: Bump. IEC 68-2-32 1975, International Electrotechnical Commission, Basic Environmental Testing Procedures, Part 2: Tests - Test Ed: Free Fall. IEC 60529 2001-2, International Electrotechnical Commission, Degrees of Protection Provided by Enclosures (IP Code). IEEE C95.1-1991, Institute of Electrical and Electronic Engineers, Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 Ghz. ISO 9001:2000, International Organization for Standardization 9001, Quality Systems - Model for Quality Assurance in Design, Development, Production, Installation and Servicing. ISO 10012-1:1993-01-15, International Standards Organization, Quality Assurance Requirements for Measuring Equipment, Part 1: Metrological Confirmation System for Measuring Equipment. ISO 10012-2:1997-09-15, International Standards Organization, Quality Assurance for Measuring Equipment, Part 2: Guidelines for Control Measurement Process. ISO 17025:1999-12-15, International Standards Organization, General Requirements for the Competence of Testing and Calibration Laboratories. MIL-STD-461E Method RS101, Military Standard, Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment, Method RS101, Radiated Susceptibility, Magnetic Field, 30 Hz to 100 kHz. MIL-STD-810F Method 501.4, Military Standard, Test Method Standard for Environmental Engineering Considerations and Laboratory Tests, Method 501.4, High Temperature. MIL-STD-810F Method 502.4, Military Standard, Test Method Standard for Environmental Engineering Considerations and Laboratory Tests, Method 502.4, Low Temperature. MIL-STD-810F Method 505.4, Military Standard, Test Method Standard for Environmental Engineering Considerations and Laboratory Tests, Method 505.4, Solar Radiation (Sunshine). MIL-STD-810F Method 507.4, Military Standard, Test Method Standard for Environmental Engineering Considerations and Laboratory Tests, Method 507.4, Humidity. MIL-STD-810F Method 509.4, Military Standard, Test Method Standard for Environmental Engineering Considerations and Laboratory Tests, Method 509.4, Salt Fog. NILECJ Standard-0602.00, National Institute of Law Enforcement and Criminal Justice, Hand-Held Metal Detectors for Use in Weapons Detection. Safety Code, Recommended Safety Procedures for the Selection, Installation and Use of Active Metal Detectors, Radiation Protection Bureau, Canadian Minister of National Health and Welfare. UL 60950, Underwriters Laboratories, Safety for Information Technology Equipment. ---------------------------- About the Law Enforcement and Corrections Standards and Testing Program The Law Enforcement and Corrections Standards and Testing Program is sponsored by the Office of Science and Technology of the National Institute of Justice (NIJ), U.S. Department of Justice. The program responds to the mandate of the Justice System Improvement Act of 1979, which directed NIJ to encourage research and development to improve the criminal justice system and to disseminate the results to Federal, State, and local agencies. The Law Enforcement and Corrections Standards and Testing Program is an applied research effort that determines the technological needs of justice system agencies, sets minimum performance standards for specific devices, tests commercially available equipment against those standards, and disseminates the standards and the test results to criminal justice agencies nationally and internationally. The program operates through: The Law Enforcement and Corrections Technology Advisory Council (LECTAC), consisting of nationally recognized criminal justice practitioners from Federal, State, and local agencies, which assesses technological needs and sets priorities for research programs and items to be evaluated and tested. The Office of Law Enforcement Standards (OLES) at the National Institute of Standards and Technology, which develops voluntary national performance standards for compliance testing to ensure that individual items of equipment are suitable for use by criminal justice agencies. The standards are based upon laboratory testing and evaluation of representative samples of each item of equipment to determine the key attributes, develop test methods, and establish minimum performance requirements for each essential attribute. In addition to the highly technical standards, OLES also produces technical reports and user guidelines that explain in nontechnical terms the capabilities of available equipment. The National Law Enforcement and Corrections Technology Center (NLECTC), operated by a grantee, which supervises a national compliance testing program conducted by independent laboratories. The standards developed by OLES serve as performance benchmarks against which commercial equipment is measured. The facilities, personnel, and testing capabilities of the independent laboratories are evaluated by OLES prior to testing each item of equipment, and OLES helps the NLECTC staff review and analyze data. Test results are published in Equipment Performance Reports designed to help justice system procurement officials make informed purchasing decisions. Publications are available at no charge through the National Law Enforcement and Corrections Technology Center. Some documents are also available online through the Internet/World Wide Web. To request a document or additional information, call 800-248-2742 or 301-519-5060, or write: National Law Enforcement and Corrections Technology Center P.O. Box 1160 Rockville, MD 20849-1160 E-Mail: asknlectc@nlectc.org World Wide Web address: http://www.nlectc.org This document is not intended to create, does not create, and may not be relied upon to create any rights, substantive or procedural, enforceable at law by any party in any matter civil or criminal. Opinions or points of view expressed in this document represent a consensus of the authors and do not represent the official position or policies of the U.S. Department of Justice. The products and manufacturers discussed in this document are presented for informational purposes only and do not constitute product approval or endorsement by the U.S. Department of Justice. The National Institute of Justice is a component of the Office of Justice Programs, which also includes the Bureau of Justice Assistance, the Bureau of Justice Statistics, the Office of Juvenile Justice and Delinquency Prevention, and the Office for Victims of Crime. ---------------------------- NCJ 200330