Specifically, the project had the following three objectives: 1) increase the fundamental understanding of the relationship between DNA input and signal so as to provide recommendations for DNA validation experimental design; 2) provide algorithms and prototype software that combines the features of a fully continuous model to calculate the LR and its distribution, conditioned on the defense hypothesis; and 5) provide interpretation approaches that use novel algorithms and signal information produced by the laboratory to reduce the need to continuously re-evaluate validation data. The method was tested on 306 1-, 2-, and 3-person electropherograms containing between 0.016 and 1 ng of DNA. The amount of template DNA from the contributor had an impact on the LR; small LRs arose from contributors with low template masses, indicating that high levels of dropout and stutter could decrease the probability of the evidence under the prosecution's hypothesis, even for true contributors. Since researchers used 109 samples to calculate the p-value; the lowest possible p-value that can be achieved is 10-9 , and this was obtained in all the cases in which the LR was greater than 108. The results from MatchIt were found to be repeatable after duplicate runs on all the samples in the testing set. 3 figures, 2 tables, and 3 references
Downloads
Similar Publications
- Principles of Fluorogenic Reagent Design for Forensics. Recent Progress Towards New Reagents to Develop Fingerprints in Blood and on Variable Surfaces
- Y-SNP Typing of US African-American and Caucasian Samples Using Allele-Specific Hybridization and Primer Extension
- Genetic mapping of 15 human X chromosomal forensic short tandem repeat (STR) loci through multi-core parallelization