A multistep classification scheme was used to detect and classify ignitable liquid residues in fire debris into the classes defined by the ASTM E1618-10 standard method. The total ion spectra (TIS) of the samples were classified by soft independent modeling of class analogy (SIMCA) with cross-validation and tested on fire debris. For detection of ignitable liquid residue, the true-positive rate was 94.2% for cross-validation and 79.1% for fire debris, with false-positive rates of 5.1% and 8.9%, respectively. Evaluation of SIMCA classifications for fire debris relative to a reviewer's examination led to an increase in the true-positive rate to 95.1%; however, the false-positive rate also increased to 15.0%. The correct classification rates for assigning ignitable liquid residues into ASTM E1618-10 classes were generally in the range of 80-90%, with the exception of gasoline samples, which were incorrectly classified as aromatic solvents following evaporative weathering in fire debris. Abstract published by arrangement with Wiley.
Progress Toward the Determination of Correct Classification Rates in Fire Debris Analysis II: Utilizing Soft Independent Modeling of Class Analogy (SIMCA)
NCJ Number
246001
Journal
Journal of Forensic Sciences Volume: 59 Issue: 4 Dated: July 2014 Pages: 927-942
Date Published
July 2014
Length
16 pages
Annotation
A multistep classification scheme was used to detect and classify ignitable liquid residues in fire debris into the classes defined by the ASTM E1618-10 standard method.
Abstract